Morris Moor Building 4

Tender Details

Quotes Due By 28 Jun 2022
Project Name Morris Moor Building 4
Address 1 Cochranes Road, Moorabbin VIC 3189 Australia
Project Budget $20m - $30m
Lead Estimator Jamie Barbacena (jamie.barbacena@kapitolgroup.com.au)

Tender Description

Morris Moor is a multi-use development by Up Property on the former Phillip Morris site.
The development commenced in 2017 and several successful stages have been completed including for office, childcare, retail, industrial and hospitality uses.

The current stage for tender is primarily based in and around Building 4 and is generally summarised as follows:

Site
 Northern car park (accessed from Sullivan Street) to be refurbished for on-grade car parking including new pedestrian paths, screening, and entry into Building 4 through the existing loading bay area.
 Eastern on-grade car parking (accessed from Cochranes Road) to be realigned and extended to the east with new retaining wall.
 New landscape works to the garden and gatehouse areas on Cochranes Rd including sunken courtyard access to basement tenancies.

Basement
Reuse of existing basement for:
 Undercover car parking to the north side
 New tenancy base works on the south side
 Bike storage, end of trip facilities and lobby to the south east

Ground Floor
 New double height west lobby and level 1 tenancy providing access and activation from the west F&B courtyard; including new stair and lift access.
 New east lobby including new stair from ground to level 1 and new lift access from basement to level 1. Existing guardhouse to be refurbished.

Level 1
Refurbishment of the existing level 1 space into:
 Commercial office space on the south side including inter tenancy partitions, common lobbies, corridors, amenities, internal courtyards and break out areas. Office scope includes stripped down warm shell including installation of lighting and air conditioning ready for tenancy fit out by others.
 Industrial / warehousing space on the north side (cold shell including lighting and fire services) including 2x vertical risers with lift and stair access from ground to level 1

Building Fabric
 External walls – brick walls to be retained, made good and insulated to achieve required thermal Values to ESD requirements.
 Windows – as per architect’s drawings. Where possible retaining the frames and upgrading to double glazing in office areas in accordance with ESD requirements . (Compliance confirmed to meet NCC-BCA 2016 amendment 1)
 Roof - Existing roof is a combination of Kingspan insulated panel and metal sheeting. Insulation of existing roof required in parts for offices as per ESD requirements.
 New skylights added above offices and common areas.
 Services and Civil improvements as documented

Trades Involved

Demolition
  • Demolition
Civil
  • Civil Works
Groundworks
  • Piling
  • Tanking & Waterproofing ( Substr...
Insitu Concrete
  • Structure
Precast concrete
  • Precast Concrete
Steelwork
  • Structural Steel
Brickwork & Blockwork
  • Masonry
Roofing Systems
  • Roof Access Systems
Window Systems
  • Aluminium Windows
Cladding Systems
  • Balustrades
Doors & Frames
  • Door Hardware
  • Door Supply
  • Roller Doors
Suspended Ceilings & Partitions
  • Suspended Ceilings & Plasterboar...
Carpentry
  • Carpentry
Sanitary Accessories
  • Sanitary Hardware
Woodwork
  • Joinery
Furnishings
  • Acoustic Panels
  • Toilet Partitions
Metalwork
  • Lockers
  • Metalwork
Office Fitout
  • Internal Glass Partitions
Signage
  • Signage
Floor Coverings
  • Carpet
  • Floor Finishes
  • Stair Nosings & Tactiles
Tiling
  • Stonework
  • Tiling
Applied
  • Concrete Polishing
  • Epoxy Floor Coating
  • Painting
Landscaping
  • Landscaping
  • Timber Decking
Hydraulic
  • Hydraulic Services
Electrical
  • Electrical
  • Security
  • Solar Panels
Mechanical
  • Mechanical Services
Fire
  • Fire Services
Transport Services
  • Lifts
Consultants
  • Consultants
  • Programme